You’re read light novel Some Mooted Questions in Reinforced Concrete Design Part 4 online at NovelOnlineFull.com. Please use the follow button to get notification about the latest chapter next time when you visit NovelOnlineFull.com. Use F11 button to read novel in full-screen(PC only). Drop by anytime you want to read free – fast – latest novel. It’s great if you could leave a comment, share your opinion about the new chapters, new novel with others on the internet. We’ll do our best to bring you the finest, latest novel everyday. Enjoy

TEST NO. 1.[I]

Marks on column--none.

Reinforcement--eight 1-1/8-in. round bars vertically.

Band s.p.a.cing--- 9 in. vertically.

Hooped with seven 32-in. wire spirals about 2-in. raise.

Outside diameter of hoops--14-1/2 in.

Total load at failure--1,360,000 lb.

Remarks.--Point of failure was about 22 in. from the top. Little indication of failure until ultimate load was reached.

Some slight breaking off of concrete near the top cap, due possibly to the cap not being well seated in the column itself.

TEST NO. 2.

Marks on column--Box 4.

Reinforcement--eight 1-1/8-in. round bars vertically.

Band s.p.a.cing about 13 in. vertically.

Wire spiral about 3-in. pitch.

Point of failure about 18 in. from top.

Top of cast-iron cap cracked at four corners.

Ultimate load--1,260,000 lb.

Remarks.--Both caps apparently well seated, as was the case with all the subsequent tests.

TEST NO. 3.

Marks on column--4-B.

Reinforcement--eight 7/8-in. round bars vertically.

Hoops--1-3/4 in. 3/16 in. 14 in. outside diameter.

Band s.p.a.cing--13 in. vertically.

Ultimate load--900,000 lb.

Point of failure about 2 ft. from top.

Remarks.--Concrete, at failure, considerably disintegrated, probably due to continuance of movement of machine after failure.

TEST NO. 4.

Marks on column--Box 4.

Reinforcement--eight 1-in. round bars vertically.

Hoops s.p.a.ced 8 in. vertically.

Wire spirals as on other columns.

Total load at failure--1,260,000 lb.

Remarks.--First indications of failure were nearest the bottom end of the column, but the total failure was, as in all other columns, within 2 ft. of the top. Large cracks in the sh.e.l.l of the column extended from both ends to very near the middle. This was the most satisfactory showing of all the columns, as the failure was extended over nearly the full length of the column.

TEST NO. 5.

Marks on column--none.

Reinforcement--eight 7/8-in. bars vertically.

Hoops s.p.a.ced 10 in. vertically.

Outside diameter of hoops--14-1/2 in.

Wire spiral as before.

Load at failure--1,100,000 lb.

Ultimate load--1,130,000 lb.

Remarks.--The main point of failure in this, as in all other columns, was within 2 ft. of the top, although this column showed some scaling off at the lower end.

In these tests it will be noted that the concrete outside of the hooped area seems to have had very little value in determining the ultimate strength; that, figuring the compression on the core area and deducting the probable value of the vertical steel, these columns exhibited from 5,000 to 7,000 lb. per sq. in. as the ultimate strength of the hooped area, not considering the vertical steel. Some of them run over 8,000 lb.

The concrete mixture was 1 part Alpena Portland cement, 1 part sand, 1-1/2 parts buckwheat gravel and 3-1/2 parts gravel ranging from 1/4 to 3/4 in. in size.

The columns were cast in the early part of December, and tested in April. The conditions under which they hardened were not particularly favorable, owing to the season of the year.

The bands used were 1-3/4 by 1/4 in., except in the light column, where they were 1-3/4 by 3/16 in.

In his remarks regarding the tests at Minneapolis, Minn., Mr. G.o.dfrey has failed to note that these tests, faulty as they undoubtedly were, both in the execution of the work, and in the placing of the reinforcement, as well as in the character of the hooping used, were sufficient to satisfy the Department of Buildings that rational design took into consideration the amount of hooping and the amount of vertical steel, and on a basis not far from that which the writer considers reasonable practice.

Again, Mr. G.o.dfrey seems to misunderstand the influence of Poisson's ratio in multiple-way reinforcement. If Mr. G.o.dfrey's ideas are correct, it will be found that a slab supported on two sides, and reinforced with rods running directly from support to support, is stronger than a similar slab reinforced with similar rods crossing it diagonally in pairs. Tests of these two kinds of slabs show that those with the diagonal reinforcement develop much greater strength than those reinforced directly from support to support. Records of small test slabs of this kind will be found in the library of the Society.

Please click Like and leave more comments to support and keep us alive.

RECENTLY UPDATED MANGA

Eternal Sacred King

Eternal Sacred King

Eternal Sacred King Chapter 2943: Deterrence Author(s) : Snow-filled Bow Saber, 雪满弓刀 View : 5,300,945
Unscientific Beast Taming

Unscientific Beast Taming

Unscientific Beast Taming Chapter 1738: World King's Mission (1) Author(s) : Ligh Spring Flow, 轻泉流响 View : 1,260,943
Fey Evolution Merchant

Fey Evolution Merchant

Fey Evolution Merchant Chapter 2978: The Amazing Lin Yuan! Author(s) : 琥珀纽扣, Amber Button View : 8,133,035
Keyboard Immortal

Keyboard Immortal

Keyboard Immortal Chapter 2131: The Final Lesson Author(s) : 六如和尚, Monk Of The Six Illusions View : 1,382,910

Some Mooted Questions in Reinforced Concrete Design Part 4 summary

You're reading Some Mooted Questions in Reinforced Concrete Design. This manga has been translated by Updating. Author(s): Edward Godfrey. Already has 491 views.

It's great if you read and follow any novel on our website. We promise you that we'll bring you the latest, hottest novel everyday and FREE.

NovelOnlineFull.com is a most smartest website for reading manga online, it can automatic resize images to fit your pc screen, even on your mobile. Experience now by using your smartphone and access to NovelOnlineFull.com